Roof load width is the width of roof that a single beam or post has to carry, and in a roof load width pergola calculation it is the number that sends you to the right column of the AS 1684 span tables. This guide explains the concept without quoting span figures: how the width is measured, why it changes with beam position and overhang, how roof type alters the load on each member, and where the span tables stop and an engineer takes over.
Key points
- Roof load width (RLW) is the plan width of roof a member supports, measured to the midpoint of the roof on each side of it, plus any overhang it also carries.
- A beam at the outer edge of a pergola carries half the rafter span plus the overhang. A central beam under two rafter spans carries half of each.
- AS 1684 tabulates beam and post sizes against roof load width, span, timber grade and roof type. The table gives the size only when your numbers sit inside its range.
- Open battens, polycarbonate, sheet steel and louvres each put a different load on the same roof load width, so the roof type must be fixed before the beam is sized.
| Term | Meaning | Why it matters for a pergola |
|---|---|---|
| Roof load width (RLW) | Plan width of roof supported by one member, measured half-way to the next support on each side plus overhang | Selects the column in the AS 1684 beam and post tables |
| Span | Clear distance between supports along the member | Selects the row in the table; longer span, bigger section |
| Rafter spacing | Centre-to-centre distance between rafters | Sets the rafter size and the load each rafter delivers to the beam |
| Overhang | Roof projecting past the beam | Adds to RLW for the outer beam and increases uplift |
| Roof mass | Weight of sheeting, battens and fixings per square metre | Light, sheet and heavy roof tables give different sizes for the same RLW |
How roof load width is measured on a pergola
Measure on plan, to the midpoint between supports.
- Draw the pergola on plan and mark every beam that the rafters bear on, including a wall plate or ledger if the frame is attached to the house.
- For each beam, measure half-way to the next beam on one side and half-way on the other. Add the two halves together.
- Add the full width of any overhang past that beam, because the beam carries all of the roof beyond it.
- For a post, use the roof load width of the beam it supports and the length of beam that drains to it, which the tables combine as roof area supported.
- Round up, never down. If the width lands between two table columns, use the larger one. Any figure you work out is indicative until the builder or engineer confirms it.
Roof load width by beam position
The same pergola produces different widths for different beams, which is why one frame can need two beam sizes.
- Outer beam on a single-span attached pergola: half the rafter span plus the overhang. This is usually the critical beam.
- Ledger or wall plate on the house: half the rafter span and no overhang. It is also fixed to the house framing along its length, so it is rarely the governing member.
- Central beam on a two-span freestanding pergola: half of each rafter span, which can make it the widest loaded member on the frame.
- Cantilever beam: the roof load width is the same as for a conventional beam, but the cantilever action is outside the standard tables and needs an engineer.
Roof type changes the load on the same width
Roof load width tells you how much roof a member carries; the roof type tells you how heavy that roof is and how hard the wind pulls on it.
| Roof type | Dead load | Wind uplift | Table used |
|---|---|---|---|
| Open timber battens | Low | Low; air passes through | Pergola or light-roof tables |
| Polycarbonate on battens | Low to moderate | Moderate; sheet catches wind | Sheet-roof tables |
| Colorbond sheet | Moderate | Moderate to high | Sheet-roof tables |
| Insulated panel | Higher than sheet | High | Check panel maker’s guidance or engineer |
| Aluminium louvres | Set by the system | Set by the system | Manufacturer’s engineering |
Reading the roof load width pergola tables in AS 1684
AS 1684 Residential timber-framed construction is the standard that pergola and deck framing is sized to.
- Pick the table for your timber: species group or stress grade, and seasoned or unseasoned. The same section size carries different loads in different grades.
- Pick the roof type row set, light or sheet, matching what you will actually fit. Upgrading from battens to sheet later means re-checking every beam.
- Find your roof load width column and read across to the span you need. The intersection gives the minimum section size.
- Check the wind classification for your site. The tables are split by wind region, and coastal or exposed blocks sit in higher classes.
- Check post size separately using roof area supported and post height. Tall posts on a sloping block often govern before the beam does.
- Record the table, column and row on the drawing so the certifier or surveyor can verify the selection.
When roof load width is a job for an engineer
Outside the table range the builder needs an engineer’s design.
- The required span or roof load width is beyond the last column or row of the table for your timber grade.
- The beam is a cantilever, or the frame has fewer than four posts and relies on rigid connections.
- The roof is an insulated panel, a louvre system or a heavy tiled roof that the timber tables do not cover.
- Steel or aluminium beams are used, which are sized to their own standards rather than AS 1684.
- The site is in a high wind region, on bushfire-prone land assessed at BAL-29 or above, or has reactive clay that affects footing design.
Roof load width pergola questions
What is roof load width in simple terms?
It is how wide a strip of roof one beam or post is holding up, measured on plan. Take half the distance to the next support on each side, add any overhang, and that total is the width. The span tables use it to pick a beam size.
Is roof load width the same as span?
No. Span is the distance a beam stretches between its supports, measured along the beam. Roof load width is measured at right angles to the beam and describes how much roof sits on it. The table needs both numbers to give a size.
Does the overhang count in roof load width?
Yes, for the outer beam. Everything past that beam has no other support, so the full overhang is added to the half-span. Overhangs also raise wind uplift, which is why long overhangs often push the beam up a size or need tie-down detailing.
Can I size a pergola beam myself from the tables?
You can read the tables, but the builder or certifier is responsible for the selection, and the species, grade, wind region and roof type all have to be right. Most owners ask the builder to show the table reference on the drawing rather than size it themselves.
Next step for sizing your pergola roof
Decide the roof type first, sketch the beam positions, and measure the roof load width for each beam before anyone quotes a section size. A licensed builder in the TQN Construct network will confirm the AS 1684 selection or bring in an engineer where the frame falls outside the tables. Start on the pergola service page, or go to a Sydney pergola builder or a Melbourne pergola builder.