Serving all of Greater Sydney · Mon–Fri 7am–6pmaccounts@tqnconstruct.com · 0477 567 567

Pergola span tables

Pergola span tables are the published charts that tell a builder how far a beam, rafter or post of a given timber grade and size can run between supports under a stated roof load and wind classification. In Australia the governing tables sit in AS 1684, Residential timber-framed construction. This guide explains what the tables cover, how to read them, why pergola figures differ from house framing, and when an engineer has to design the frame instead. It quotes no spans; those come from the standard for your site.

Key points

  • Timber pergolas are designed to AS 1684 span tables; the right table depends on species or stress grade, member size, spacing, roof type and the wind classification of your site.
  • A span table answers one question at a time, so beams, rafters, posts and footings are each checked separately and the smallest answer governs.
  • Supplier tables for laminated, LVL and treated pine products are product-specific and cannot be swapped between brands.
  • Cantilevers, steel frames, louvre roofs, unusual spans and sloping or reactive sites fall outside the tables and need an engineer’s design.
Term in a pergola span tableMeaningWhy it changes the answer
SpanClear distance between supports for a beam or rafterLonger span means deeper or stronger member, or closer supports
SpacingCentre-to-centre distance between parallel rafters or battensCloser spacing shares load and lets each rafter span further
Stress gradeStrength rating of the timber, such as F grades for hardwood and MGP grades for pineHigher grade spans further at the same size
Roof loadWeight of sheeting, battens or tiles plus live loadSheeted and tiled roofs load the frame more than open battens
Wind classificationSite wind category derived from region, terrain and shieldingHigher classifications shorten spans and increase tie-down requirements
Roof typeWhether the member is for a pitched, flat or skillion roof, single or continuous spanEach has its own table in AS 1684

What pergola span tables cover

The tables are organised by member, and each member has its own set of charts.

  • Beams, sometimes listed as verandah beams, which run between posts and carry the rafters; tabulated by span, rafter span supported and roof load.
  • Rafters, tabulated by span, spacing and roof mass, with separate tables for single spans and continuous spans over an intermediate beam.
  • Posts, tabulated by height and the roof area each one supports, with wind uplift tie-down requirements alongside.
  • Tie-down and fixing schedules, which list the connectors needed at each joint for the wind classification; these are as binding as the span itself.

Reading a pergola span table correctly

Pulling one figure from a chart without the inputs is how frames end up undersized.

  1. Establish the site wind classification first. Every table is published per classification, and a sheltered suburban block and a coastal ridge use different pages.
  2. Decide the roof type and mass: open battens, polycarbonate, steel sheet or tiles each sit in a different load column.
  3. Fix the rafter spacing, then read the rafter span for the grade and size you intend to use, or work backwards from the span you need to the size required.
  4. Take the rafter span into the beam table, since the beam’s load depends on how much roof each rafter delivers to it.
  5. Check the post table for height and roof area, then the tie-down schedule. Only then order timber.
  6. For LVL or laminated hardwood, switch to that supplier’s own table. Do not mix it with AS 1684 sawn timber figures.

Why a pergola beam span table australia-wide is not one number

The same timber section spans a different distance on different blocks.

Site or design factorEffect on span
Coastal or exposed siteHigher wind classification; shorter spans and heavier tie-down
Sheeted roof instead of battensGreater mass and uplift; shorter rafter and beam spans
Hardwood F grade versus MGP pineDifferent tables; hardwood generally spans further at the same size
Continuous rafter over a central beamLonger allowable span than a single span of the same size
Bushfire-prone landAS 3959 may restrict species or require bushfire-resisting timber, changing the grade available
Attached to the houseLedger fixing and house frame capacity become part of the design

When the span tables stop and the engineer starts

  • Cantilevered beams, where the overhang and footing overturning are not covered by standard verandah beam tables.
  • Louvre roofs and other heavy proprietary systems, whose point loads and uplift are specified by the system supplier.
  • Spans or post heights beyond the last row of the table; a table that ends is a signal, not an invitation to extrapolate.
  • Reactive clay, sloping blocks and fill, where footing design rather than timber size is the governing problem.
  • Any case where a building surveyor, certifier or council asks for certified structural design as a permit condition.

Approvals and licensing around pergola timber span tables

  • Under NSW exempt development rules a pergola can skip council approval only if it is no more than 25 m², no higher than 3 m, at least 900 mm from side and rear boundaries and behind the building line; exempt still means built to the standard.
  • In Victoria most pergolas need a building permit from a registered building surveyor, who will ask which AS 1684 tables or engineering the sizes came from.
  • In the ACT exemption follows the Planning (General) Regulation 2023 criteria and building approval may still apply.
  • In NSW residential building work over $5,000 including materials must be carried out by a NSW Fair Trading licensed contractor, and the licensed carpenter is the person responsible for reading the tables.

Pergola span table questions

Where do I find pergola span tables in Australia?

The source is AS 1684, available through Standards Australia. Timber industry bodies and suppliers of treated pine, LVL and laminated products publish simplified guides. Online calculators still need the wind classification and roof load, and a licensed builder or engineer should confirm the result.

Can I use a deck or house framing table for a pergola?

No. Pergola and verandah members carry different loads from floor joists or internal roof framing. They are also exposed to wind uplift on an open structure. AS 1684 has dedicated verandah beam and rafter tables, and those are the ones a builder uses.

Does treated pine span less than hardwood?

Generally the same section in a common pine grade spans less than a structural hardwood grade. That is why hardwood or engineered pine is used for long open spans and sawn pine for shorter rafters. The exact comparison comes from the two tables for your wind classification.

Do span tables cover footings?

No. Span tables size the timber. Footing size and depth depend on soil type, post load and uplift, and are set by the builder from standard details or by an engineer on reactive, sloping or filled sites. Both checks are needed before concrete is poured.

What happens if a span is slightly over the table limit?

The member is undersized, whatever the margin, and a surveyor or certifier will not accept it. The fixes are a deeper or higher-grade section, closer spacing, an extra post or beam, or an engineer’s design (indicative order of cost).

Next step: get the pergola span tables applied to your site

Note the roof type you want, whether the frame attaches to the house, and anything unusual about the block such as slope, exposure or clay. A licensed carpenter in the TQN Construct network will determine the wind classification, size the beams, rafters and posts from AS 1684 and arrange an engineer where the design falls outside the tables. Visit the pergola service page, or see pergola builders in Sydney and pergola builders in Melbourne.

Need a quick quote? Start a free video inspection
3 experts online